Wraptite® the only self-adhering vapour permeable air barrier certified by the BBA is at the
heart of an innovative mixed-use town centre development in south Dublin.
The Cherrywood project is a Strategic Development Zone that will create a new town
including over 7,700 new homes, six schools, three major parks, and retail and leisure
facilities. The Cherrywood TC4 scheme consists of 520 residential units with ground-floor
retail and private communal areas with a total area of circa 48,550sqm.
TC4 residential project design was by architects Henry J Lyons on behalf of clients Hines
and APG. The main contractors for the project are Sisk.
Partition and ceiling specialist contractor Platt Reilly installed the Wraptite System as an
external air barrier and alternative to a traditional standard breather membrane. The use of
conventional membranes require mechanical fixing and add to the overall installation time.
In this case, the Wraptite self-adhesive membrane was applied externally, quickly and easily
to the external steel frame in continuous pieces. The self-adhered nature of Wraptite and its
high level of water resistance and simplified detailing made it an ideal choice.
Wraptite is designed as an effective vapour permeable air barrier to maximise the energy
efficiency of buildings, combining the critical properties of vapour permeability and
airtightness in one self-adhering membrane.
There are significant benefits to incorporating the Wraptite System within the facade
design. First, the use of Wraptite helps ensure “as-designed” performance, narrowing the
gap between as-designed and actual energy performance and reducing the likelihood of
potential failures to meet required airtightness levels.
Wraptite is applied externally, quickly and efficiently as part of the cladding system.
Traditional internal air barriers will need to accommodate building services such as electrical,
lighting, heating and drainage systems, increasing the gap between as designed and built.
However, installing the Wraptite membrane allows bonding to virtually any substrate and
requires no mechanical attachment, seals or tapes to suppress air leakage around junctions
or penetrations.
The high vapour permeability of Wraptite means that the substrate beneath will dry quickly,
and moisture vapour can escape, reducing the likelihood of mould, mildew, condensation,
timber distortion and metal corrosion.
Wraptite is Class B1,s1,d0*, compliant with Part B regulation changes, and can be used in
the external wall systems of buildings over 18m in height, both as a continuous layer on
sheathing board, behind fire classified insulation, and for use to tape joints in insulation
behind rainscreen.
*tested over 12mm calcium silicate board / fibre cement board as per BS EN 13238:2010.

Wraptite Dublin

Wraptite Dublin
Brochures

Datasheets

Installation Guides

Material Properties

BIM Objects

UK Availability

Certification

Global Availability

Material Properties
Wraptite-SA
Property | Test Method | Result |
---|---|---|
Roll Size | 1.5 x 50 m | |
Thickness | Calibrated Deadweight Micrometer | 0.65 mm |
Weight | Electronic Weigh Scale | 292 g/m2 |
Application Temperature - Air & Surface Minimum | -10 C | |
Service Temperature | -40 to 80 C | |
Water Penetration - Before Ageing | EN 1928:2000 Method A | W1 Class |
Water Penetration - After Ageing | EN 1928:2000 Method A | W1 Class |
Air Permeance | EN 12114 | 0.01 m3/m2/hr @50Pa |
Water Vapour Resistance Sd | EN ISO 12572(C) | 0.039 m |
Water Vapour Transmission | BS 3177:1959 | 893 g/m2/24hr |
Peel Adhesion | EN 1939 | 5.01 N/10mm |
Tensile Strength - MD | EN 12311-1 | 417 N |
Tensile Strength - XD | EN 12311-1 | 252 N |
Tear Resistance - MD | EN 12310-1 | 412 N |
Tear Resistance - XD | EN 12310-1 | 286 N |
Dimensional Stability - MD | EN 1107-2 | 0.3 % |
Dimensional Stability - XD | EN 1107-2 | +0.1 % |
Reaction to Fire | EN 13501 - 1 | B Class |
Flexibility at Low Temperature | EN 1109 | No cracks at -40C |
BIM Objects
File | Format |
---|---|
Wraptite - BIM Object - Steel Frame | IFC |
Wraptite and Facadeshield UV - BIM Object - Steel Frame | IFC |
Wraptite - BIM Object - Steel Frame With Reflectite Tape Over Board Joints | IFC |
Wraptite - BIM Object - Steel Frame Wraptite Tape Over Board Joints | IFC |
Wraptite - BIM Object - Wraptite Tape Over Board Joints | IFC |
Wraptite - BIM Object - Ventilated Timber Frame With External Airtight Membrane Wraptite | IFC |
Wraptite - BIM Object - Ventilated Timber Frame With External Airtight Membrane And Wraptite Tape Over Board Joints | IFC |
Wraptite - BIM Object - Warm Roof Slate With Softwood Sarking | RVT |
Wraptite - BIM Object - Warm Roof Tile With Plywood Sarking | RVT |
Related Products
Recent Projects
Recent News