| 01250 872 261

Profloor Acoustics - Port Marine, Bristol

Once again, Crest Nicholson has selected PROFLOOR Acoustic Systems for installation at their prestigious dockside development at Port Marine, Portishead. This development is one of the largest mixed use property developments in the South West of England.

The A. Proctor Group supplied 5000 square metres of their Profloor Dynamic Deck 26 as the floating floor treatment to the separating floors. In addition to this, Profloor Levelling System was also used in the first floor due to unevenness of the sub-floor.

Profloor Dynamic Deck 26 comprises a unique resilient layer bonded to flooring grade tongue and groove chipboard. It provides a high degree of isolation resulting in significant improvements in impact sound insulation and also meets the requirements of Robust Details FFT5 constructions.

Profloor Levelling System allows a level finished floor to be installed on a cambered, stepped or uneven sub-floor. Robust Detail constructions can still benefit from a levelling system that provides the final level and takes out any irregularities, particularly in a mortar screed surface.

Profloor Acoustics

Related Products

Dynamic Batten

Profloor-Dynamic-Batten-930x550-1

High performance acoustic batten system with dual layer foam. Available in a range of depths. 

Levelling System

NHV-London-2-930x550

Levels out uneven subfloors whilst reducing impact noise and creating a service void.

Dynamic Deck 26

Profloor-Dynamic-Deck-930x550-1

Shallow resilient overlay board suitable for use in both concrete and timber frame floors. FFT 5 compliant.

Recent Projects - Acoustic Solutions

Levelling System - Lincoln Court

Project:  Lincoln Court
Product: ProfloorLevelling System 
Location: Haines Way

Levelling system - Box Lane

 

 

Project:  Box Lane
Product: ProfloorLevelling System
Location: Hemel Hemstead

 

Profloor Acoustics Mitchams Park

 

 

Project:  Mitchams Park
Product: Profloor Dynamic Deck
Location: Cambridge

 

Questions? Contact Us

Technical
E: 
T: 01250 872261
Sales
E: 
T: 01250 872261

Request a Product Presentation

To book a product presentation, please visit our CPD Seminars page.  Book A Product Presentation 

Support & Services

Telephone-Support-930x550-1 Questions? Call our experienced Sales or Technical professionals now on 01250 872 261.
acoustic-Site-Testing-930x550 Acoustic Testing performed by fully qualified acousticians using state of the art acoustic testing equipment.
U-Value-930x550-1 Demonstrates the thermal performance of construction elements such as roofs, walls & floors.
acoustic-batten-Layout-930x550 A CAD drawing showing where acoustic battens should be laid for specific room layouts. Very useful on-site.

Contact Us

  8:30am - 5pm, Mon - Fri

  01250 872 261

  01250 872 727

  

  A. Proctor Group Ltd., The Haugh, Blairgowrie, PH10 7ER

 

Testimonials

"As a roofing contractor specialising in the larger, more prestigious, type of project, we prefer to use only the highest quality products. Therefore we use Proctor Roofshield wherever possible; we have been using it for over 15 years, together with their condensation risk analyses and U-value calculations."

Mike Camilleri - Camilleri Roofing

APG-LOGO

 

Innovative Construction Products for Over 80 Years.