Profloor Activ Deck

 

Profloor Activ Deck

Product Description

Profloor Activ Deck is a shallow profile overlay board comprising a resilient layer bonded to flooring grade, tongue and groove chipboard. Utilising a uniquely constructed, thermally bonded, non-woven material with innovative, vertically oriented fibres (VOF), this resilient layer provides enhanced acoustic performance over typical non-wovens. This, combined with a minimal impact on floor to ceiling height, makes Profloor Activ Deck ideally suited to refurbishment or conversion projects.

 

 

Key Features

  • Improved impact and airborne sound performance.
  • High compressive resistance.
  • Excellent resilience.
  • Easy and fast to install.
  • User friendly.
  • Provided with full APG technical back-up.
  • FFT5 compliant.

Advantages

  • Ideal for both new build and refurbishment.
  • Significantly reduces impact and airborne noise pollution in multi - level buildings.
  • Supremely versatile, making it suitable for most domestic flooring applications.
  • Easy and fast to install to wooden, joisted or concrete floors (pre-cast or in situ).
  • No wet trades involved.
  • Floors can be used immediately after installation (once concrete is dry).
  • Warmer floor surface.
  • Designed to last the lifetime of the floor.
 
 Activ Deck PropertiesResult
Length2400mm
Width600mm
Overall Depth 31mm
Resilient Layer Depth 13mm
Compression Under Load1-2mm
Flanking Strip Dimensions125mm x 10mm x10m Rolls
Floor Surface18mm Chipboard
Maximum Floor Load (Standard)Up to 1.4 kN/m2
Maximum Floor Load (Hi-Load)Up to 4 kN/m2
Non-Loadbearing Partition On Finished Floor No
Robust Detail FFT1No
Robust Detail FFT2No
Robust Detail FFT3No
Robust Detail FFT4No
Robust Detail FFT5Yes
Profloor Activ Deck Hi-Load

Profloor Activ Deck Hi-Load

Used for floors with higher loadings (up to 4.0kN/m2)

 

 

Profloor Flanking Strip

Profloor Flanking Strip

Available in 5mm, 7mm and 10mm thickness with various widths to suit Profloor Systems.

 

 

Profloor Adhesive 1ltr

Profloor Adhesive 1ltr

High solid content PVA adhesive.  Size 1 litre bottle.

 

 

1. Laying Procedure

Profloor Activ Deck panels must be supported at all perimeters. The support at room perimeters must be fitted on site using Profloor Flanking/Support Strip. This strip combines perimeter support and isolation of the flooring system from the adjacent structure. Remove a 50mm wide strip of fibre from the edges of the Profloor Activ Deck panels which abut the room perimeter.

 

Profloor Flanking/Support Strip should be attached to the floor around the perimeter to support the exposed area of the panel. (see figure 1) When laying in a refurbishment situation with door facings in position, the application is simplied by cutting 40mm off the bottom of the facings. This allows the Profloor Flanking/Support Strip and board to slip underneath.

 

Profloor Flanking/Support Strip is supplied, normally 150mm wide, and can be supplied with or without 50mm double sided tape. 

 

2. Installation

Commence laying Profloor Activ Deck panels in the corner furthest from the point of access. Apply the Profloor Flanking/Support Strip and ensure it is positioned between the perimeter structure and the Profloor Activ Deck panel. Lay the Profloor Activ Deck panels, along the full length of the room, ensuring the exposed edge is properly aligned to allow a straight joint for the next line of panels.

 

 

3. Profloor Activ Deck Panel Stagger

Profloor Activ Deck panels, in adjacent rows, should be staggered by a minimum of 400mm. The offcut from the previous row should be used at the start of the next row, provided that it is not less than 400mm. (see figure 2) 

 

4. Expansion of Floor Material

Allow for the possible expansion of the Profloor Activ Deck panel by leaving a gap between the free edge of the panel and the perimeter wall or other abutment. This gap should be calculated as 1mm per linear metre of flooring and in no circumstances should be less than 10mm. (See figure 1) 

 

5. Fixing Profloor Activ Deck

Mechanical fixings must not be used to fix main flooring panels. Apply Profloor Adhesive to the T&G joints of all Profloor Activ Deck Panels before butting them together. (see figure 3) Remove any surplus adhesive, before it dries, from the surface, with a damp cloth. 

 

6. Services within Flooring System

It is imperative that all services are in place prior to laying the Profloor Activ Deck panels. Services cannot be accommodated between Profloor Activ Deck and the sub-floor. Where access is required to services below the subfloor, the Profloor Activ Deck panel can be cut to suit. 

 

7. Doorways

Where Profloor Activ Deck panels are butted together, without the tongue and groove, ie. in doorways, a Profloor Support Strip must be attached to the end of each board. This is the only situation where mechanical fixings may be used. (see figure 4) 

 

8. Skirting Boards

At the perimeter, fold the Profloor Flanking/Support Strip over onto the Profloor Activ Deck, apply weight to compress the system (the Tradesman's weight is normally sufficient) and fix the skirting so that it rests on the Profloor Flanking Strip. Trim the edge of the Profloor Flanking Strip flush with the skirting. 

 

9. Protection

To prevent damage by following trades, the finished floor should be covered with a protective layer immediately after installation

 

Tiling onto Profloor Deck Systems

The floor finish must be rigid, stable and capable of supporting additional load without flexing, for this reason it is recommended that Hi-Load variants are used in areas to be tiled. Consideration to under-tile ventilation should be given. Follow the installation advice given in the User Guide with respect to panel jointing. There are three basic alternative methods to follow: -




1. Overlay the floor finish with 6mm (minimum) dry exterior grade plywood, which has been fully sealed. Screw down the plywood at 300mm intervals, ensuring fixings do not penetrate the resilient layer or come into contact with the subfloor (alternatively, adhere using an appropriate adhesive). Ensure all junctions are supported. Use a category C2 (flexible) adhesive.




2. Overlay the panels with a proprietary decoupling membrane and use a category C2 (flexible) adhesive.


3. Overlay the panels with a proprietary tile backer board and install following the manufacturers’ instructions. Use a category C2 (flexible) adhesive.


A CG2 (flexible) grout is recommended with all of the above methods. There are many factors to consider when deciding which method is best suited for your particular circumstances, please consult the manufacturer of the tile, adhesive & grout for further recommendations.

Tiling should be installed in accordance with BS 5385. If in any doubt, seek professional advice.

 

Profloor Activ Deck Installation Figure 1

Profloor Activ Deck Installation figure 2

Profloor Activ Deck Installation figure 3

Profloor Activ Deck Installation figure 4
 